CIMac AAV full/empty 0.1 mL Analytical Column (1.3 µm)

CIMac AAV Analytical Columns are intended for fast and reproducible analysis and quantification in Adeno-associated virus (AAV) processes.

With a resolution high enough to resolve empty and full virus capsids and high volumetric flow ratesm they provide information about the product quantity and purity within minutes.

Item No.: 
110.8503-1.3
Piece
1
*Custom/bulk order quotes are provided within 72 hours of request.
CIMac AAV full/empty 0.1 mL Analytical Column (1.3 µm)
CIMac AAV full/empty 0.1 mL Analytical Column (1.3 µm)

CIMac AAV Analytical Columns are intended for fast and reproducible analysis and quantification in Adeno-associated virus (AAV) processes.

With a resolution high enough to resolve empty and full virus capsids and high volumetric flow ratesm they provide information about the product quantity and purity within minutes.

Item No.:
110.8503-1.3
Number of pieces
1

Overview

Specifications

The CIMac AAV full/empty 0.1 mL Analytical Columns are designed for fast and reproducible HPLC monitoring and quantitation of AAV samples. The high resolving capacity allows separation of empty viral capsids, aggregated and damaged particles from genome containing virus vectors. CIMac AAV full/empty-01 Analytical Column works with a full range of AAV serotypes and samples ranging from crude harvest all the way to final formulation, therefore doubling as an efficient PAT tool.

AAV full/empty features:

  • Strong anion exchanger
  • Enables fast and reproducible analysis and quantification in Adeno-associated virus (AAV)
  • Enables separation of empty and full virus capsids

Applications

  • Application
    Analytical Columns

Connections (Physical)

  • Connector(s)
    10-32 UNF coned port, 0.0625" OD tubing connection

Dimensions

  • Channel Size
    1.3 µm
  • Diameter
    5.2 mm
  • Length
    4.95 mm

Features

  • Reusable
    Yes

General Specifications

  • Flow Rate
    0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min

Materials of Construction

  • Materials of Construction
    Poly(glycidyl methacrylate -co- ethylene dimethacrylate)

Operating Conditions

  • Maximum Operating Pressure
    15 MPa | 150 bar | 2175 psi
  • Recommended Operating Temperature
    4 °C (39 °F) to 40 °C (104 °F)
  • pH Stability
    Working range 2–13, cleaning in place 1–14

Physicochemical Information

  • Bed Volume
    0.1 mL
  • Ligand
    QA modified for AAV (strong anion exchanger, quaternary amine)