Our eShop will be on maintenance from May 15th 2026, 3:00 PM until May 17th 2026, 10:00 PM CEST. Please note that during this time the eShop will be available with limited functionality only.

CIMac Adeno 0.1 mL Analytical Column (2 µm)

CIMac Adeno Analytical Columns are intended for fast and reproducible analysis and quantification of Adenovirus samples at different stages of downstream and upstream.

Item No.: 
110.8502-2
Piece
1
*Custom/bulk order quotes are provided within 72 hours of request.
CIMac Adeno 0.1 mL Analytical Column (2 µm)
CIMac Adeno 0.1 mL Analytical Column (2 µm)

CIMac Adeno Analytical Columns are intended for fast and reproducible analysis and quantification of Adenovirus samples at different stages of downstream and upstream.

Item No.:
110.8502-2
Number of pieces
1

Overview

Specifications

The CIMac Adeno-0.1 Analytical Columns are intended for fast and reproducible HPLC monitoring and quantitation of any type of Adenovirus. They were primarily designed for the in-process and final control of Adenovirus samples at different stages of the purification process. They can be operated at high volumetric flow rates (from 1 to 20 column volumes/min); therefore, the information about the Adenovirus quantity and purity can be obtained within a few minutes. CIMac Adeno-0.1 Analytical Columns are fast and reliable PAT tools, providing:

  • Rapid, high resolution analysis, achieved in minutes
  • Flow independent separation
  • High sensitivity and reproducibility

Adeno features:

  • Strong anion exchanger
  • Enables fast and reproducible HPLC monitoring and quantitation of any type of Adenovirus

Applications

  • Application
    Analytical Columns

Connections (Physical)

  • Connector(s)
    10-32 UNF coned port, 0.0625" OD tubing connection

Dimensions

  • Channel Size
    2 µm
  • Diameter
    5.2 mm
  • Length
    4.95 mm

Features

  • Reusable
    Yes

General Specifications

  • Flow Rate
    0.2 – 3 mL/min | 1 – 15 cm/min | 2 – 30 CV/min

Materials of Construction

  • Materials of Construction
    Poly(glycidyl methacrylate -co- ethylene dimethacrylate)

Operating Conditions

  • Maximum Operating Pressure
    15 MPa | 150 bar | 2175 psi
  • Recommended Operating Temperature
    4 °C (39 °F) to 40 °C (104 °F)
  • pH Stability
    Working range 2–13, cleaning in place 1–14

Physicochemical Information

  • Bed Volume
    0.1 mL
  • Ligand
    QA modified for Adeno (strong anion exchanger, quaternary amine)
  • Typical Dynamic Binding Capacity 10% per mL
    25–31 mg BSA/mL wet support, BSA, 0.5 mg/mL, 20 mM Tris-HCI buffer, pH 7.4, flowrate 1 mL/min

Product Information

  • Brand
    CIMac™