Choose your product

Most used filters

Filter by product attributes

Chromatography Monoliths (63)

  • CIMmultus® QA HR 800 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-921.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    800 mL
    Channel Size
    2 µm
  • CIMmultus® QA HR 1 mL Monolithic Column (2 μm)
    Item no.
    BIA-311.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    1 mL
    Channel Size
    2 µm
  • CIMmultus® QA HR 80 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-911.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    80 mL
    Channel Size
    2 µm
  • CIMmultus® QA HR 8 mL Monolithic Column (2 μm)
    Item no.
    BIA-411.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    8 mL
    Channel Size
    2 µm
  • CIMmultus® SDVB 40 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    914.9001-2
    Application
    Gene therapy, Polishing
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
    Bed Volume
    40 mL
    Channel Size
    2 µm
  • CIMmultus® SDVB 4000 mL Monolithic Column (2 μm)
    Item no.
    1014.9001-2
    Application
    Gene therapy, Polishing
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
    Bed Volume
    4000 mL
    Channel Size
    2 µm
  • CIMmultus® SDVB 8000 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    931.9001-2
    Application
    Gene therapy, Polishing
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
    Bed Volume
    8000 mL
    Channel Size
    2 µm
  • CIMmultus® QA HR 400 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-924.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® QA HR 8000 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-931.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    8000 mL
    Channel Size
    2 µm
  • CIMmultus® QA HR 4 mL Monolithic Column (2 μm)
    Item no.
    BIA-414.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    4 mL
    Channel Size
    2 µm
  • CIMmultus® QA HR 4000 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-934.5213-2
    Application
    Preparative Applications, Polishing
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    4000 mL
    Channel Size
    2 µm
  • CIM® Oligo dT18 0.05 mL Monolithic 96-well Plate (C6 Linker) (2 µm channels)
    Item no.
    BIA-122.1218-2
    Application
    Gene therapy, Capture, Screening
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® QA 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5113-2
    Application
    Gene therapy, Polishing, Screening
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® PrimaS 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5118-2
    Application
    Gene therapy, Capture, Screening
    Ligand
    Multimodal (anion exchange-hydrogen bonding)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® DEAE 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5114-2
    Application
    Gene therapy, Polishing, Capture, Screening
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • Results per page: | |