Choose your product

Most used filters

Filter by product attributes

Chromatography Monoliths (234)

  • CIMmultus PrimaS® 8 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    901.5118-2
    Application
    Preparative Applications
    Ligand
    Multimodal (anion exchange-hydrogen bonding)
    Bed Volume
    8 mL
    Channel Size
    2 µm
  • CIMmultus® OH 400 mL cGMP Compliant Monolithic Column (2 µm)
    Item no.
    924.8140-2
    Application
    Preparative Applications
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® CDI 4000 mL Monolithic Column (2 μm)
    Item no.
    BIA-1014.8000-2
    Application
    Preparative Applications
    Ligand
    CDI (activated; carboxy imidazole)
    Bed Volume
    4000 mL
    Channel Size
    2 µm
  • CIMmultus® SO3 4 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    904.6157-2
    Application
    Preparative Applications
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Bed Volume
    4 mL
    Channel Size
    2 µm
  • CIMmultus® SO3 4000 mL cGMP Compliant Monolithic Column (6 μm)
    Item no.
    BIA-934.6157-6
    Application
    Preparative Applications
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Bed Volume
    4000 mL
    Channel Size
    6 µm
  • CIMmultus® OH 8000 mL Monolithic Column (6 µm)
    Item no.
    1011.8140-2
    Application
    Preparative Applications
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    8000 mL
    Channel Size
    2 µm
  • CIMmultus PrimaS® 400 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    924.5118-2
    Application
    Preparative Applications
    Ligand
    Multimodal (anion exchange-hydrogen bonding)
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® C4 HLD 8 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    901.8136-2
    Application
    Preparative Applications
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
    Bed Volume
    8 mL
    Channel Size
    2 µm
  • CIMmultus® Oligo dT18 (C12 Linker) 8 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    901.1219-2
    Application
    Preparative Applications
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
    Bed Volume
    8 mL
    Channel Size
    2 µm
  • CIMmultus® SO3 800 mL Monolithic Column (6 μm)
    Item no.
    BIA-921.6157-6
    Application
    Preparative Applications
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Bed Volume
    800 mL
    Channel Size
    6 µm
  • CIMmultus® SO3 4000 mL Monolithic Column (6 μm)
    Item no.
    BIA-1014.6157-6
    Application
    Preparative Applications
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Bed Volume
    4000 mL
    Channel Size
    6 µm
  • CIMmultus® OH 80 mL Monolithic Column (6 µm)
    Item no.
    611.8140-6
    Application
    Preparative Applications
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    80 mL
    Channel Size
    6 µm
  • CIMmultus® OH 400 mL Monolithic Column (2 µm)
    Item no.
    814.8140-2
    Application
    Preparative Applications
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® DEAE 8 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    901.5114-2
    Application
    Preparative Applications
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Bed Volume
    8 mL
    Channel Size
    2 µm
  • CIMmultus® Oligo dT18 (C12 Linker) 4 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-904.1219-2
    Application
    Preparative Applications
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
    Bed Volume
    4 mL
    Channel Size
    2 µm
  • Results per page: | |