Choose your product

Most used filters

Filter by product attributes

Chromatography Monoliths (75)

  • CIMmultus® Oligo dT18 (C12 Linker) 400 mL Monolithic Column (2 μm)
    Item no.
    814.1219-2
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® DEAE 800 mL cGMP Compliant (2 μm)
    Item no.
    921.5114-2
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Bed Volume
    800 mL
    Channel Size
    2 µm
  • CIMmultus® OH 400 mL Monolithic Column (2 µm)
    Item no.
    814.8140-2
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® QA 8 mL Monolithic Column (6 µm)
    Item no.
    411.5113-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    8 mL
    Channel Size
    6 µm
  • CIMmultus® QA 4 mL Monolithic Column (6 µm)
    Item no.
    414.5113-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    4 mL
    Channel Size
    6 µm
  • CIMmultus® QA 80 mL Monolithic Column (6 µm)
    Item no.
    611.5113-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    80 mL
    Channel Size
    6 µm
  • CIMmultus® QA HR 400 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-924.5213-2
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® SDVB 400 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    924.9001-2
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
    Bed Volume
    400 mL
    Channel Size
    2 µm
  • CIMmultus® SDVB 800 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    921.9001-2
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
    Bed Volume
    800 mL
    Channel Size
    2 µm
  • CIMmultus® OH 40 mL cGMP Compliant Monolithic Column (6 µm)
    Item no.
    BIA-914.8140-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    40 mL
    Channel Size
    6 µm
  • CIMmultus® OH 80 mL cGMP Compliant Monolithic Column (6 µm)
    Item no.
    911.8140-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    80 mL
    Channel Size
    6 µm
  • CIMmultus® OH 40 mL Monolithic Column (6 µm)
    Item no.
    614.8140-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    40 mL
    Channel Size
    6 µm
  • CIMmultus® OH 4 mL Monolithic Column (6 µm)
    Item no.
    BIA-414.8140-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    4 mL
    Channel Size
    6 µm
  • CIMmultus® C4 HLD 40 mL Monolithic Column (6 μm)
    Item no.
    BIA-614.8136-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
    Bed Volume
    40 mL
    Channel Size
    6 µm
  • CIMmultus® C4 HLD 80 mL Monolithic Column (6 μm)
    Item no.
    611.8136-6
    Maximum Operating Pressure
    1.4 MPa | 14 bar | 200 psi
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
    Bed Volume
    80 mL
    Channel Size
    6 µm
  • Results per page: | |