Choose your product
Most used filters
Filter by product attributes
Chromatography Monoliths (63)
Added to Shopping Cart
Item no.
120.5114-2
Application
Gene therapy, Polishing, Capture, Screening
Ligand
DEAE (weak anion exchanger, diethylamino)
Bed Volume
0.2 mL
Channel Size
2 µm
Item no.
120.5118-2
Application
Gene therapy, Capture, Screening
Ligand
Multimodal (anion exchange-hydrogen bonding)
Bed Volume
0.2 mL
Channel Size
2 µm
Item no.
120.5113-2
Application
Gene therapy, Polishing, Screening
Ligand
QA (strong anion exchanger, quaternary amine)
Bed Volume
0.2 mL
Channel Size
2 µm
Item no.
BIA-124.8140-2
Application
Gene therapy, Capture, Screening
Ligand
OH (hydrophobic, hydroxyl)
Bed Volume
1 mL
Channel Size
2 µm
Item no.
120.5114-1.3
Application
Gene therapy, Polishing, Capture, Screening
Ligand
DEAE (weak anion exchanger, diethylamino)
Bed Volume
0.2 mL
Channel Size
1.3 µm
Item no.
120.8140-2
Application
Gene therapy, Capture, Screening
Ligand
OH (hydrophobic, hydroxyl)
Bed Volume
0.2 mL
Channel Size
2 µm
Item no.
120.6157-2
Application
Gene therapy, Capture, Screening
Ligand
SO3 (strong cation exchanger, sulfonate)
Bed Volume
0.2 mL
Channel Size
2 µm
Item no.
BIA-124.6157-2
Application
Gene therapy, Capture, Screening
Ligand
SO3 (strong cation exchanger, sulfonate)
Bed Volume
1 mL
Channel Size
2 µm
Item no.
BIA-122.9001-2
Application
Gene therapy, Polishing, Screening
Ligand
SDVB (reverse phase, poly(styrene-co-divinylbenzene))
Bed Volume
0.05 mL
Channel Size
2 µm
Item no.
BIA-122.1012-2
Application
Gene therapy, Screening
Ligand
r-Protein A (affinity, recombinant protein A produced from E. Coli coupled to CDI-preactivated support)
Bed Volume
0.05 mL
Channel Size
2 µm
Item no.
BIA-122.5113-1.3
Application
Gene therapy, Polishing, Screening
Ligand
QA (strong anion exchanger, quaternary amine)
Bed Volume
0.05 mL
Channel Size
1.3 µm
Item no.
BIA-122.5114-6
Application
Gene therapy, Polishing, Capture, Screening
Ligand
DEAE (weak anion exchanger, diethylamino)
Bed Volume
0.05 mL
Channel Size
6 µm
Item no.
BIA-122.5113-6
Application
Gene therapy, Polishing, Screening
Ligand
QA (strong anion exchanger, quaternary amine)
Bed Volume
0.05 mL
Channel Size
6 µm
Item no.
BIA-120.9001-2
Application
Gene therapy, Polishing, Screening
Ligand
SDVB (reverse phase, poly(styrene-co-divinylbenzene))
Bed Volume
0.2 mL
Channel Size
2 µm
Item no.
BIA-122.8140-6
Application
Gene therapy, Capture, Screening
Ligand
OH (hydrophobic, hydroxyl)
Bed Volume
0.05 mL
Channel Size
6 µm