Choose your product
Chromatography Monoliths (17)
Added to Shopping Cart
Item no.
934.1218-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
Oligo dT18 coupled to CDI-activated matrix, C6 Linker
Bed Volume
4000 mL
Item no.
1014.8136-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
C4 HLD (hydrophobic, butyl – high ligand density)
Bed Volume
4000 mL
Item no.
100.0019-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Bed Volume
4000 mL
Channel Size
2 µm
Item no.
934.5114-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
DEAE (weak anion exchanger, diethylamino)
Bed Volume
4000 mL
Item no.
1014.5113-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
QA (strong anion exchanger, quaternary amine)
Bed Volume
4000 mL
Item no.
934.5113-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
QA (strong anion exchanger, quaternary amine)
Bed Volume
4000 mL
Item no.
934.6157-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
SO3 (strong cation exchanger, sulfonate)
Bed Volume
4000 mL
Item no.
934.1219-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
Oligo dT18 coupled to CDI-activated matrix, C12 Linker
Bed Volume
4000 mL
Item no.
1014.1218-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
Oligo dT18 coupled to CDI-activated matrix, C6 Linker
Bed Volume
4000 mL
Item no.
101.0019-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Bed Volume
4000 mL
Channel Size
2 µm
Item no.
934.8136-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
C4 HLD (hydrophobic, butyl – high ligand density)
Bed Volume
4000 mL
Item no.
1014.1219-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
Oligo dT18 coupled to CDI-activated matrix, C12 Linker
Bed Volume
4000 mL
Item no.
1014.6157-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
SO3 (strong cation exchanger, sulfonate)
Bed Volume
4000 mL
Item no.
1014.5114-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
DEAE (weak anion exchanger, diethylamino)
Bed Volume
4000 mL
Item no.
BIA-934.5213-2
Column Tube Length
205 mm
Maximum Operating Pressure
0.7 MPa | 7 bar | 100 psi
Ligand
QA (strong anion exchanger, quaternary amine)
Bed Volume
4000 mL