Choose your product

Most used filters

Filter by product attributes

Chromatography Monoliths (38)

  • CIM® Monolithic Well Plates

    Product Family

    CIM® Monolithic Well Plates

    CIM® Monolithic Well Plates ensure robust and reliable results for screening multiple chromatographic conditions simultaneously or high-throughput purification of large biomolecules such as viruses, nucleic acids, exosomes, bacteriophages, etc.

    Available in:


    24-well or 96-well plate design
    Varied monolith volumes
    Wide range of CIM® chemistries

    Show all Products
  • CIM® C4 HLD 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.8136-2
    Application
    Gene therapy, Polishing, Screening
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® DEAE 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5114-2
    Application
    Gene therapy, Polishing, Capture, Screening
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® Oligo dT18 0.05 mL Monolithic 96-well Plate (C6 Linker) (2 µm channels)
    Item no.
    BIA-122.1218-2
    Application
    Gene therapy, Capture, Screening
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® QA 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5113-2
    Application
    Gene therapy, Polishing, Screening
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® PrimaS 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5118-2
    Application
    Gene therapy, Capture, Screening
    Ligand
    Multimodal (anion exchange-hydrogen bonding)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® OH 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.8140-2
    Application
    Gene therapy, Capture, Screening
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® SDVB 0.05 mL Monolithic 96-well Plate (2 μm channels)
    Item no.
    BIA-122.9001-2
    Application
    Gene therapy, Polishing, Screening
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® r-Protein G LLD 0.05 mL Monolithic 96-well Plate (recombinant Protein G, low ligand density) (2 μm channels)
    Item no.
    BIA-122.1012-2
    Application
    Gene therapy, Screening
    Ligand
    r-Protein A (affinity, recombinant protein A produced from E. Coli coupled to CDI-preactivated support)
    Bed Volume
    0.05 mL
    Channel Size
    2 µm
  • CIM® QA 0.05 mL Monolithic 96-well Plate (1.3 μm channels)
    Item no.
    BIA-122.5113-1.3
    Application
    Gene therapy, Polishing, Screening
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    0.05 mL
    Channel Size
    1.3 µm
  • CIM® DEAE 0.05 mL Monolithic 96-well Plate (6 μm channels)
    Item no.
    BIA-122.5114-6
    Application
    Gene therapy, Polishing, Capture, Screening
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Bed Volume
    0.05 mL
    Channel Size
    6 µm
  • CIM® QA 0.05 mL Monolithic 96-well Plate (6 μm channels)
    Item no.
    BIA-122.5113-6
    Application
    Gene therapy, Polishing, Screening
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Bed Volume
    0.05 mL
    Channel Size
    6 µm
  • CIM® SDVB 0.2 mL Monolithic 96-well Plate (2 μm channels)
    Item no.
    BIA-120.9001-2
    Application
    Gene therapy, Polishing, Screening
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
    Bed Volume
    0.2 mL
    Channel Size
    2 µm
  • CIM® OH 0.05 mL Monolithic 96-well Plate (6 μm channels)
    Item no.
    BIA-122.8140-6
    Application
    Gene therapy, Capture, Screening
    Ligand
    OH (hydrophobic, hydroxyl)
    Bed Volume
    0.05 mL
    Channel Size
    6 µm
  • CIM® PrimaS 0.2 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    120.5118-2
    Application
    Gene therapy, Capture, Screening
    Ligand
    Multimodal (anion exchange-hydrogen bonding)
    Bed Volume
    0.2 mL
    Channel Size
    2 µm
  • Results per page: | |