Choose your product

Narrow your results

Most used filters

Filter by product attributes

Chromatography Consumables (Media) (516)

  • CIMmultus® QA 80 mL Monolithic Column (6 µm)
    Item no.
    611.5113-6
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications
  • CIMmultus® SO3 80 mL Monolithic Column (6 μm)
    Item no.
    611.6157-6
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
    Application
    Preparative Applications
  • CIMmultus® QA HR 400 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-924.5213-2
    Bed Volume
    400 mL
    Column Tube Length
    75 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 40 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-914.5213-2
    Bed Volume
    40 mL
    Column Tube Length
    55 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 8000 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-931.5213-2
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 4 mL Monolithic Column (2 μm)
    Item no.
    BIA-414.5213-2
    Bed Volume
    4 mL
    Column Tube Length
    18.6 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 800 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-921.5213-2
    Bed Volume
    800 mL
    Column Tube Length
    150 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 1 mL Monolithic Column (2 μm)
    Item no.
    BIA-311.5213-2
    Bed Volume
    1 mL
    Column Tube Length
    3.8 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 80 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-911.5213-2
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 8 mL Monolithic Column (2 μm)
    Item no.
    BIA-411.5213-2
    Bed Volume
    8 mL
    Column Tube Length
    32.6 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® QA HR 4000 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-934.5213-2
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
    Ligand
    QA (strong anion exchanger, quaternary amine)
    Application
    Preparative Applications, Polishing
  • CIMmultus® DEAE 1 mL Monolithic Column (6 μm)
    Item no.
    311.5114-6
    Bed Volume
    1 mL
    Column Tube Length
    4.2 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • CIMmultus® DEAE 80 mL Monolithic Column (6 μm)
    Item no.
    611.5114-6
    Bed Volume
    80 mL
    Column Tube Length
    110 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • CIMmultus® C4 HLD 8000 mL cGMP Compliant Monolithic Column (6 μm)
    Item no.
    BIA-931.8136-6
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
    Application
    Preparative Applications
  • CIMmultus® DEAE 8 mL Monolithic Column (6 μm)
    Item no.
    411.5114-6
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
    Application
    Preparative Applications
  • Results per page: | |