Choose your product
Products (55)
Added to Shopping Cart
-
-
Flexsafe® RM
-
Polyethersulfone (PES) 1.2 μm
-
Preclinical and clinical studies
-
Biostat® RM 200 L
-
-
-
Flexsafe® RM
-
Polyethersulfone (PES) 1.2 μm
-
Preclinical and clinical studies
-
Biostat® RM 200 L
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 200 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L, Biostat® RM TX
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 200 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L, Biostat® RM TX
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L, Biostat® RM TX
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L, Biostat® RM TX
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells
-
-
-
Flexsafe® RM
-
Biostat® RM 20 | 50 L, Biostat® RM TX
-
Preclinical and clinical studies
-
Mammalian cell culture, Insect cell culture, Microbial Fermentation, Low molecular weight binding, Shear-stress-sensitive cells such as stem cells, Low to medium density microbial cultures
-
The bags are mainly clustered in Basic, Optical, Perfusion and RM TX bags. Some configurations include optical sensors, biomass sensor, screw caps or perfusion membrane.
Applications
-
Application
-
Mammalian cell culture
-
Insect cell culture
-
Microbial Fermentation
-
Low molecular weight binding
- Shear-stress-sensitive cells such as stem cells
-
Mammalian cell culture
-
Application AreaPreclinical and clinical studies
Compliance Information
-
Biocompatibility (USP Class VI)
-
Class VI
-
USP87 and ISO 10993-5; USP 88
-
USP<88>
- USP 87: Pass | USP 88: Pass
-
Class VI
Components
-
Gas FiltersHEPA rated hydrophobic filter or Sartopore® Air Midisart
Features
-
Sensors
-
Optical DO
- Optical pH
-
Optical DO
General Specifications
-
pH RangepH 6.0 – 8.0
Materials of Construction
-
Film MaterialS80
Operating Conditions
-
Operating Conditions - Temperature16 – 40°C (specified by the hardware)
Physicochemical Information
-
Pressure RangeOperation pressure: 6 mbar [g] - 30 mbar [g]
Product Information
-
BrandFlexsafe® RM
Usage Protocols
-
Gamma Irradiation≥25 kGy