Sartovent DG Cartridge 0.2 µm Size 6

Sartovent DG filter cartridges are used for sterile venting of transport containers, the removal of particles and the sterile filtration of liquids and gases.

Pack Size
Price (USD):
$935.00
Item No.: 
5181807T6------D
Availability: 
Pieces
10

*Custom/bulk order quotes are provided within 72 hours of request.

Product Information

Sartovent DG Air Filters are used for the removal of particles and the sterile filtration of liquids and gases.

Applications

  • Sterile venting of transport containers
  • Sterile air filtration during fermentation
  • Sterile filtration of compressed air | gases that is required for filling and draining of tanks, containers, filling machines, autoclaves or lyophililizers

Flushing

For the filtration of gases, no flushing is required before use. For the filtration of liquids, flushing could be reasonable for ensuring the absence of any particles in the entire system.

Autoclaving

Sartovent DG filter cartridges should be autoclaved at 134°C. and 2 bar for at least 20 minutes after the sterilization temperature has been reached.

In-line Steam Sterilization

Sartovent DG can be steam sterilized in-line in either direction at 134°C. and 2 bar for at least 20 minutes after the sterilization temperature has been reached. In order to prolong the life of the membrane, the differential pressure between the inlet and the outlet sides should not exceed 0.5 bar. A vacuum due to condensation during the cooling phase can be avoided by cooling the filter system after steam sterilization with either compressed air or nitrogen at a pressure of 0.2 bar higher than the pressure used for sterilization.

Steaming Cycles

Up to 50 cycles of 20 min at 134°C (2 bar) in the direction of filtration and opposite direction.

Flow Capacity

Despite the relatively small filtration area, its minimal flow resistance allows draining velocities of 1000 l within only 10 min.

Permanent Hydrophobicity

The PTFE membrane has the highest hydrophobicity of all membranes for air | gas filtration. Even repeated autoclaving or steaming does not change its characteristics. The sterile filtration of dry or moist air | gas is guaranteed.

Available Adapter

18 layout type, double O-Ring type

Integrity Testing

Using the Sartorius Stedim Biotech Sartocheck® Integrity Test System, the bubble point, diffusion and pressure hold tests can be performed automatically and the corresponding data recorded. For parallel manual testing of the Bubble Point, a multi-filter-housing is available.

Accessories Information

  • Adapter
    18 (Plug adapter with double O-ring)

Applications

  • Application
    Air/Gas Filtration
  • Application Area
    • Bioreactors (Inlet | Outlet)
    • Storage tank venting
    • Filling equipment venting
    • Venting
  • Industry
    Pharma / Biotech / F&B

Biological Information

  • Bacterial Retention
    Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology

Compliance Information

  • Bacterial Endotoxins
    < 0.25 EU/mL as determined by the LAL test
  • Biocompatibility (USP Class VI)
    USP<88>
  • Biological Reactivity
    All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
  • Extractables
    The total amount of extractables is well below the limits established by the current USP unter "Sterile Water for Injection".

Dimensions

  • Filter Size
    0.03 m² / 0.32 ft²
  • Filtration Area
    0.03 m² / 0.32 ft²

General Specifications

  • Capsule/Cartridge Format
    Mini Cartridges
  • Maximum Allowable Back Pressure
    21 °C: 3 bar, 121 °C: 1.5 bar, 134 °C: 0.5 bar
  • Maximum Diffusion
    2 mL/min at 0.7 bar l 10 psi at 20 °C
  • Minimum Required Bubble Point
    ≥ 1.0 bar | 14.5 psi

Materials of Construction

  • Filter Material
    Polytetrafluorethylene (PTFE)
  • Housing Material
    Polypropylene (PP)
  • Membrane Material
    Polytetrafluorethylene (PTFE)

Operating Conditions

  • Maximum Differential Pressure
    21 °C: 5 bar, 121 °C: 1.5 bar, 134 °C: 0.5 bar

Physicochemical Information

  • Gamma Stable
    No
  • Pore Size
    0.2 µm

Product Information

  • Brand
    Sartovent
  • Pack Size
    10
  • Type
    Air filter

Sterility/Purity

  • Delivery Condition
    Non-Sterile
  • Sterilization Method
    Autoclavable & In-Line Steam Sterilizable
  • Sterilizing Grade
    Yes

Usage Protocols

  • Sterilization Procedures
    • In-Line Steam Sterilization: at 134°C and 2 bar l 29 psi, 20 min. at max differential pressure of 0.5 bar | 7 psi
    • Autoclaving: at 134°C, 2 bar | 29 psi, 20 min. or other parameters to be specified