Choose your product

  • Shop
  • Chromatography

Narrow your results

Most used filters

Filter by product attributes

Chromatography (55)

  • CIM® DEAE 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5114-2
    Application
    Gene therapy, Polishing, Capture, Screening
    Bed Volume
    0.05 mL
    Column Tube Length
    2.5 mm (Monolith)
    Ligand
    DEAE (weak anion exchanger, diethylamino)
  • CIM® OH 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.8140-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    0.05 mL
    Column Tube Length
    2.5 mm (Monolith)
    Ligand
    OH (hydrophobic, hydroxyl)
  • CIM® SO3 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.6157-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    0.05 mL
    Column Tube Length
    2.5 mm (Monolith)
    Ligand
    SO3 (strong cation exchanger, sulfonate)
  • CIM® Oligo dT18 0.05 mL Monolithic 96-well Plate (C12 Linker) (2 µm channels)
    Item no.
    BIA-122.1219-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    0.05 mL
    Column Tube Length
    2.5 mm (Monolith)
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
  • CIM® QA 0.05 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    BIA-122.5113-2
    Application
    Gene therapy, Polishing, Screening
    Bed Volume
    0.05 mL
    Column Tube Length
    2.5 mm (Monolith)
    Ligand
    QA (strong anion exchanger, quaternary amine)
  • CIM® PrimaS 0.2 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    120.5118-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    0.2 mL
    Column Tube Length
    4,8 mm (Monolith)
    Ligand
    Multimodal (anion exchange-hydrogen bonding)
  • CIM® Oligo dT18 1 mL Monolithic 24-well Plate (C12 Linker) (2 µm channels)
    Item no.
    BIA-124.1219-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    1 mL
    Column Tube Length
    5.8 mm (Monolith)
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
  • CIM® QA 0.2 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    120.5113-2
    Application
    Gene therapy, Polishing, Screening
    Bed Volume
    0.2 mL
    Column Tube Length
    4,8 mm (Monolith)
    Ligand
    QA (strong anion exchanger, quaternary amine)
  • CIM® OH 1 mL Monolithic 24-well Plate (2 µm channels)
    Item no.
    BIA-124.8140-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    1 mL
    Column Tube Length
    5.8 mm (Monolith)
    Ligand
    OH (hydrophobic, hydroxyl)
  • CIM® QA 1 mL Monolithic 24-well Plate (2 µm channels)
    Item no.
    BIA-124.5113-2
    Application
    Gene therapy, Polishing, Screening
    Bed Volume
    1 mL
    Column Tube Length
    5.8 mm (Monolith)
    Ligand
    QA (strong anion exchanger, quaternary amine)
  • CIM® DEAE 0.2 mL Monolithic 96-well Plate (1.3 µm channels)
    Item no.
    120.5114-1.3
    Application
    Gene therapy, Polishing, Capture, Screening
    Bed Volume
    0.2 mL
    Column Tube Length
    4,8 mm (Monolith)
    Ligand
    DEAE (weak anion exchanger, diethylamino)
  • CIM® DEAE 0.2 mL Monolithic 96-well Plate (6 µm channels)
    Item no.
    120.5114-6
    Application
    Gene therapy, Polishing, Capture, Screening
    Bed Volume
    0.2 mL
    Column Tube Length
    4,8 mm (Monolith)
    Ligand
    DEAE (weak anion exchanger, diethylamino)
  • CIM® OH 0.2 mL Monolithic 96-well Plate (2 µm channels)
    Item no.
    120.8140-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    0.2 mL
    Column Tube Length
    4,8 mm (Monolith)
    Ligand
    OH (hydrophobic, hydroxyl)
  • CIM® SDVB 1 mL Monolithic 24-well Plate (2 µm channels)
    Item no.
    BIA-124.9001-2
    Application
    Gene therapy, Polishing, Screening
    Bed Volume
    1 mL
    Column Tube Length
    5.8 mm (Monolith)
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
  • CIM® Oligo dT18 1 mL Monolithic 24-well Plate (C6 Linker) (2 µm channels)
    Item no.
    BIA-124.1218-2
    Application
    Gene therapy, Capture, Screening
    Bed Volume
    1 mL
    Column Tube Length
    5.8 mm (Monolith)
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C6 Linker
  • Results per page: | |