Choose your product

  • Shop
  • Chromatography

Narrow your results

Most used filters

Filter by product attributes

Chromatography (340)

  • CIMmultus® DEAE 4000 mL cGMP Compliant (2 μm)
    Item no.
    934.5114-2
    Reusable
    Yes
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
  • CIMmultus® C4 HLD 1 mL Monolithic Column (2 μm)
    Item no.
    311.8136-2
    Reusable
    Yes
    Bed Volume
    1 mL
    Column Tube Length
    4.2 mm
    Ligand
    C4 HLD (hydrophobic, butyl – high ligand density)
  • CIMmultus® DEAE 4000 mL Monolithic Column (2 μm)
    Item no.
    1014.5114-2
    Reusable
    Yes
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
  • CIMmultus® DEAE 8 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    901.5114-2
    Reusable
    Yes
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    DEAE (weak anion exchanger, diethylamino)
  • CIMmultus® Oligo dT18 (C12 Linker) 4 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    BIA-904.1219-2
    Reusable
    Yes
    Bed Volume
    4 mL
    Column Tube Length
    28 mm
    Ligand
    Oligo dT18 coupled to CDI-activated matrix, C12 Linker
  • CIMmultus® OH 8000 mL cGMP Compliant Monolithic Column (6 µm)
    Item no.
    BIA-931.8140-6
    Reusable
    Yes
    Bed Volume
    8000 mL
    Column Tube Length
    410 mm
    Ligand
    OH (hydrophobic, hydroxyl)
  • CIMmultus® SO3 800 mL Monolithic Column (6 μm)
    Item no.
    BIA-921.6157-6
    Reusable
    Yes
    Bed Volume
    800 mL
    Column Tube Length
    150 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
  • CIMmultus® SDVB 400 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    924.9001-2
    Reusable
    Yes
    Bed Volume
    400 mL
    Column Tube Length
    75 mm
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
  • CIMmultus® SDVB 800 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    921.9001-2
    Reusable
    Yes
    Bed Volume
    800 mL
    Column Tube Length
    150 mm
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
  • CIMmultus® OH 8 mL Monolithic Column (2 µm)
    Item no.
    411.8140-2
    Reusable
    Yes
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    OH (hydrophobic, hydroxyl)
  • CIMmultus® SO3 4000 mL Monolithic Column (6 μm)
    Item no.
    BIA-1014.6157-6
    Reusable
    Yes
    Bed Volume
    4000 mL
    Column Tube Length
    205 mm
    Ligand
    SO3 (strong cation exchanger, sulfonate)
  • CIMmultus® OH 4 mL Monolithic Column (2 µm)
    Item no.
    414.8140-2
    Reusable
    Yes
    Bed Volume
    4 mL
    Column Tube Length
    28 mm
    Ligand
    OH (hydrophobic, hydroxyl)
  • CIMmultus® OH 800 mL cGMP Compliant Monolithic Column (2 µm)
    Item no.
    921.8140-2
    Reusable
    Yes
    Bed Volume
    800 mL
    Column Tube Length
    150 mm
    Ligand
    OH (hydrophobic, hydroxyl)
  • CIMmultus® SDVB 4000 mL cGMP Compliant Monolithic Column (2 μm)
    Item no.
    934.9001-2
    Reusable
    Yes
    Bed Volume
    4000 mL
    Column Tube Length
    205
    Ligand
    SDVB (reverse phase, poly(styrene-co-divinylbenzene))
  • CIMmultus® CDI 8 mL Monolithic Column (2 μm)
    Item no.
    411.8000-2
    Reusable
    Yes
    Bed Volume
    8 mL
    Column Tube Length
    56 mm
    Ligand
    CDI (activated; carboxy imidazole)
  • Results per page: | |