Choose your product
Filter by product attributes
Sterile Filtration & Mycoplasma Removal & Bioburden Control (602)
Added to Shopping Cart
Item no.
5495307HS--FF--M
Application
Single Use Processing
Brand
Sartopore® Platinum
Filter Material
Polyethersulfone (PES)
Filtration Area
17.3 cm²
Item no.
5105307H9--FF--A
Application
Filtration of antibiotics and organic solvents
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Item no.
5445307I9--FF--A
Application
High capacity platform for conventional sterile filtration
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Item no.
5105307H9--OO--A
Application
Filtration of antibiotics and organic solvents
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Item no.
5445307I9--FO--A
Application
High capacity platform for conventional sterile filtration
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Item no.
5445306G9--FF--A
Application
High capacity platform for conventional sterile filtration
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Brand
Sartopore® 2
Item no.
5235307H9--SS--A
Application
Blood and Plasma, Vaccine Production
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Item no.
5235306D9--OO--A
Application
Blood and Plasma, Vaccine Production
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Brand
Sartobran®
Item no.
5105307H9-ESO--A
Application
Filtration of antibiotics and organic solvents
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Item no.
5105307H9-ESS--A
Application
Filtration of antibiotics and organic solvents
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Item no.
5105307H9--SO--A
Application
Filtration of antibiotics and organic solvents
Bacterial Endotoxins
< 0.25 EU/mL as determined by the LAL test
Bacterial Retention
Quantitative Retention of 1 × E7 CFU/cm² Brevundimonas Diminuta ATCC® 19146 per ASTM methodology
Biological Reactivity
All materials of this filter element meet the requirements of the current USP Biological Reactivity tests <88> for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).